STC-005 — Control Test Timeline Rate
Statement
The DIDO-TE SHALL control the progression rate of the test timeline using the rate specified by the governing Test Definition.
Source
-
[DTE1] U.S. Patent Application US20220237111A1, virtual system time progressing at rates equal to, faster than, or slower than real time
-
[DTE3] Broad Agency Announcement White Paper, State and Time Control
-
[DTE5] DIDO-TE Requirements Register, State and Time Control source requirements
Rationale
A test timeline may progress independently of wall-clock time.
The timeline rate determines how quickly test time progresses relative to elapsed wall-clock time.
The governing Test Definition specifies the required timeline rate. The DIDO-TE controls progression of the test timeline using that specified rate.
A test may require the timeline to progress at the same rate as real time, faster than real time, or slower than real time.
Controlling timeline rate allows time-dependent behavior to be exercised without requiring the duration of Test Execution to match the corresponding real-world duration.
Timeline-rate control remains distinct from establishing the timeline, setting its starting point, or resetting it. STC-003, STC-004, and STC-006 govern those separate obligations.
This requirement does not prescribe a clock implementation, simulation engine, scheduler, time service, or operating-system mechanism.
Applies To
Verification
Verification confirms that:
-
The governing Test Definition specifies a progression rate for the test timeline.
-
The test timeline progresses using the specified rate.
-
A rate equal to real time can be distinguished from a rate faster than or slower than real time.
-
The configured timeline rate can be determined independently of wall-clock time.
-
The timeline rate is traceable to the governing Test Definition.
-
Timeline-rate control does not require a particular clock service, simulation engine, scheduler, or operating-system mechanism.
Verification includes a Test Definition specifying a timeline rate different from real time and confirms that the test timeline progresses at the specified rate.
Traceability
ConOps Relationship
This requirement controls the progression rate of the test timeline established under STC-003 and initialized under STC-004.
STC-006 separately resets the test timeline for repeated execution.