The architectural description defines the structural organization of the proposed Reference Architecture, including its elements, responsibilities, relationships, interaction constructs, attachment points, processing flows, boundary constructs, and Governance abstractions.
| Requirement | Statement |
|---|---|
| SIP-044 — Structured Architectural Description |
The Submission SHALL include a structured architectural description of the proposed Reference Architecture. |
| SIP-045 — Architectural Visual Representations |
The Submission SHALL include visual representations of the ordered processing flows and boundary constructs defined by the architectural model without requiring conforming implementations to use a specific modeling notation. |
The architectural description required by SIP-044 includes the architectural information governed by the following requirements:
| Requirement | Required Architectural Information |
|---|---|
| SIP-003 — Reference Architecture Constituents | Architectural elements, roles, responsibilities, relationships, and interaction constructs |
| SIP-005 — Structured Information Flow | Architectural constructs representing the flow of structured information |
| SIP-006 — Ordered Modular Processing Flows | Ordered processing flows composed of modular components |
| SIP-007 — Structured Information Attachment Points | Attachment points through which structured information enters and exits architectural elements |
| SIP-008 — Information Boundary Constructs | Boundary constructs governing ingress, transformation, and egress |
| SIP-019 — Data Plane and Control Plane Separation | Architectural separation between the data plane and the control plane |
| SIP-020 — Governance Constraints and Interface Contracts | Separation of Governance constraints from Interface Contracts |
The requirement identifiers and short titles link to the authoritative requirement records in Annex C.
The Statements for SIP-044 and SIP-045 are transcluded from their corresponding Annex C requirement pages and are not independently maintained copies.
Make changes to a Statement on its Annex C requirement page.
The Required Coverage table provides a nonnormative summary of the architectural information governed by the referenced requirements. The corresponding Annex C records remain authoritative.
SIP-042 requires the Submission to include a complete specification addressing all applicable requirements. SIP-044 establishes that the specification includes a structured architectural description. Together, they require the architectural description to document the applicable information governed by SIP-003, SIP-005 through SIP-008, SIP-019, and SIP-020.
SIP-045 requires visual representations as specification deliverables. It does not make the notation used to create those representations mandatory for conforming implementations.