The governing Test Definition SHALL specify each Fault designated for introduction into a Node or a condition governing its operation.
Fault specification establishes the controlled conditions governing Fault Injection before the DIDO-TE introduces the Fault.
The Test Definition identifies the Fault, target Node, injection point, initiating condition, timing, duration, intensity, scope, expected effects, prohibited effects, termination conditions, and recovery conditions. It also identifies the observations and expected Node behaviour used to evaluate the effects of the Fault.
The Fault specification distinguishes the deliberately introduced condition from the Node response and the resulting Test Outcome. The occurrence of an expected response does not describe the Fault itself.
A missing, ambiguous, incomplete, or internally inconsistent Fault specification prevents controlled preparation, authorization, injection, observation, containment, termination, recovery, and evaluation.
Verification confirms that: