Table of Contents

STC-003 — Establish a Test Timeline

Go to C.3.5 State and Time Control Requirements

Statement

The DIDO-TE SHALL establish the test timeline specified by the governing Test Definition.

Source

Rationale

Distributed-system behavior may depend upon the temporal context in which test activities occur.

A test timeline provides the temporal context against which activities within a Test Environment are executed and interpreted.

The governing Test Definition specifies the test timeline required for the test. DIDO-TE establishes that timeline for use during Test Execution.

The test timeline is distinct from wall-clock time. DIDO-TE source material permits test time to be independent of real time and permits the temporal behavior of a test to be controlled without requiring equivalent passage of wall-clock time.

Establishing a test timeline is distinct from setting its starting point, controlling its rate, or resetting it. Those obligations are governed separately by STC-004, STC-005, and STC-006.

This requirement does not prescribe a clock implementation, simulation engine, time service, synchronization protocol, or operating-system time mechanism.

Applies To

Verification

Verification confirms that:

  1. The governing Test Definition specifies a test timeline.
  2. The specified test timeline is established before it is used during Test Execution.
  3. The established test timeline can be distinguished from wall-clock time.
  4. The established test timeline is traceable to the governing Test Definition.
  5. Establishment of the test timeline does not require a particular clock service, simulation engine, time-synchronization protocol, or operating-system time mechanism.

Verification includes a Test Definition specifying a test timeline and confirms that the specified timeline exists as the temporal context for Test Execution.

Traceability

ConOps Relationship

This requirement establishes the test timeline used as the temporal context for Test Execution.

STC-004 sets the timeline starting point, STC-005 controls the rate at which the timeline progresses, and STC-006 resets the timeline for repeated execution.

Delivery Phase

TBD