====== MO-007c — Air-Gapped Environment Operation ======
[[dido:03-dido-te:99-annexes:annex-c-requirements:01-mission-objectives:mo-007:start|Go to MO-007 — Connected, Disconnected, and Air-Gapped Operation]]
===== Statement =====
[[dido:99_annexes:annex-b-terms-and-definitions:d:dido-te|DIDO-TE]] SHALL perform testing operations in an [[dido:99_annexes:annex-b-terms-and-definitions:a:air-gapped_environment|Air-Gapped Environment]] that maintains physical isolation from external networks.
===== Derived From =====
MO-007c derives from [[dido:03-dido-te:99-annexes:annex-c-requirements:01-mission-objectives:mo-007:start|MO-007 — Connected, Disconnected, and Air-Gapped Operation]].
MO-007c specifies the Air-Gapped Environment portion of MO-007.
===== Rationale =====
An Air-Gapped Environment maintains physical isolation from external networks during testing operations.
Air-Gapped Environment operation requires DIDO-TE to conduct tests without an active [[dido:99_annexes:annex-b-terms-and-definitions:e:external_network_connection|External Network Connection]] or access to an [[dido:99_annexes:annex-b-terms-and-definitions:e:external_service|External Service]]. The resources required for test execution must therefore exist within the Air-Gapped Environment before test execution begins.
Authorized transfer processes introduce required testing artifacts, dependencies, configurations, test data, policies, and other resources into the Air-Gapped Environment. Authorized transfer processes also remove [[dido:99_annexes:annex-b-terms-and-definitions:t:test_result|Test Results]], logs, and [[dido:99_annexes:annex-b-terms-and-definitions:e:evidence|Evidence]] after test execution.
Applicable transfer controls preserve the integrity, provenance, and [[dido:99_annexes:annex-b-terms-and-definitions:t:traceability|Traceability]] of transferred content without compromising the physical isolation of the environment.
An Air-Gapped Environment differs from a [[dido:99_annexes:annex-b-terms-and-definitions:d:disconnected_environment|Disconnected Environment]]. A Disconnected Environment lacks active external network connectivity during the applicable operation. An Air-Gapped Environment maintains physical isolation from external networks.
===== Applies To =====
MO-007c applies to:
* [[dido:99_annexes:annex-b-terms-and-definitions:d:dido-te|DIDO-TE]]
* [[dido:99_annexes:annex-b-terms-and-definitions:a:air-gapped_environment|Air-Gapped Environments]]
* [[dido:99_annexes:annex-b-terms-and-definitions:t:test_definition|Test Definitions]]
* [[dido:99_annexes:annex-b-terms-and-definitions:c:candidate_solution|Candidate Solutions]]
* [[dido:99_annexes:annex-b-terms-and-definitions:t:test_execution|Test execution]]
* [[dido:99_annexes:annex-b-terms-and-definitions:e:external_network_connection|External Network Connections]]
* [[dido:99_annexes:annex-b-terms-and-definitions:e:external_service|External Services]]
* [[dido:99_annexes:annex-b-terms-and-definitions:t:transfer_bundle|Transfer Bundles]]
* [[dido:99_annexes:annex-b-terms-and-definitions:t:test_result|Test Results]]
* [[dido:99_annexes:annex-b-terms-and-definitions:e:evidence|Evidence]]
* [[dido:99_annexes:annex-b-terms-and-definitions:t:traceability|Traceability]]
* [[dido:99_annexes:annex-b-terms-and-definitions:a:air-gapped_environment|Air-Gapped Environment]] [[dido:99_annexes:annex-b-terms-and-definitions:o:operating_procedure|Operating Procedures]]
===== Verification =====
Verification confirms that:
- DIDO-TE performs testing operations in an Air-Gapped Environment
- The Air-Gapped Environment maintains physical isolation from external networks during test execution
- No active External Network Connection exists during test execution
- Test execution does not depend upon an External Service
- The resources required by the Test Definition exist within the Air-Gapped Environment before test execution begins
- Authorized transfer processes introduce required testing artifacts and dependencies into the Air-Gapped Environment
- Authorized transfer processes remove Test Results, logs, and Evidence from the Air-Gapped Environment
- Transfer controls preserve the integrity, provenance, and Traceability of transferred content
- Transfer operations do not compromise the physical isolation of the Air-Gapped Environment
- The Evidence identifies the Air-Gapped Environment and records the isolation conditions applicable during test execution
===== Referenced By =====
The following pages reference this requirement:
{{backlinks>.#dido:03-dido-te}}
===== Delivery Phase =====
Assign the delivery phase for MO-007c.
===== Implementation Status =====
Record the implementation status of MO-007c after reviewing the implementation plan.
===== Requirement Status =====
The proposed derived requirement requires review and acceptance.
----
===== Issues =====
Confirm the testing operations included within the scope of Air-Gapped Environment operation.
Define how DIDO-TE verifies and records the physical isolation of the Air-Gapped Environment.
Identify the authorized processes for transferring resources into and Test Results, logs, and Evidence out of an Air-Gapped Environment.
Determine whether Transfer Bundle preparation, validation, introduction, and removal require separate derived requirements beneath MO-007c.
Identify the controls that prevent transfer operations from compromising the physical isolation of the Air-Gapped Environment.
Determine how DIDO-TE identifies and records dependencies upon External Services before air-gapped test execution.
Confirm that MO-007c, together with MO-007a and MO-007b, preserves the complete approved intent of MO-007.
----